17-18 SCPI Command Reference Models 2500 and 2502 User’s Manual
Table 17-7
STATus command summary
Command Description
Default
parameter SCPI
:STATus
:MEASurement
[:EVENt]?
:ENABle <NDN>
or <NRf>
:ENABle?
:CONDition?
:OPERation
[:EVENt]?
:ENABle <NDN>
or <NRf>
:ENABle?
:CONDition?
:QUEStionable
[:EVENt]?
:ENABle <NDN>
or <NRf>
:ENABle?
:CONDition?
:PRESet
:QUEue
[:NEXT]?
:ENABle <list>
:ENABle?
:DISable <list>
:DISable?
:CLEar
Control measurement event registers:
Read the event register.
6
Program the enable register.
Read the enable register.
6
Read the condition register.
6
Control operation status registers:
Read the event register.
6
Program the enable register.
Read the enable register.
6
Read the condition register.
6
Control questionable status registers:
Read the event register.
6
Program the enable register.
Read the enable register.
6
Read the condition register.
6
Return status registers to default states.
Path to access error queue:
Read the most recent error message.
Specify error and status messages for error queue.
Read the enabled messages.
Specify messages not to be placed in error queue.
Read the disabled messages.
Clears all messages from error queue.
Note 1
Note 2
Note 3
Note 2
Note 3
Note 2
Note 3
Note 4
Note 5
Note 5
Notes:
1. Commands in this subsystem are not affected by *RST and :SYSTem:PREset. The effects of cycling power, *CLS and
:STATus:PRESet, are explained by the following notes.
2. Event registers — Power-up and *CLS clears all bits. :STATus:PRESet has no effect.
3. Enable registers — Power-up and :STATus:PRESet clears all bits. *CLS has no effect. Accepts the SCPI 1995.0 mandated (non-
decimal numeric) format (#H, #Q, or #B).
4. Error queue — Power-up and *CLS clears all bits of the registers.
5. Error queue messages — Power-up clears list of messages. *CLS and :STATus:PRESet have no effect.
6. Register query commands — The format for the response messages (ASCII, hexadecimal, octal, or binary) depends on which data
format is presently selected. See the :FORMat:SREGister command.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176
TestEquipmentDepot.com

Table of Contents

Other manuals for Keithley 2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2500 and is the answer not in the manual?

Keithley 2500 Specifications

General IconGeneral
BrandKeithley
Model2500
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals