1-4 Getting Started Models 2510 and 2510-AT User’s Manual
Rack mount kits
Model 4288-1 single fixed rack mount kit
— Mounts a single Model 2510 in a standard
19-inch rack.
Model 4288-2 side-by-side rack mount kit
— Mounts two instruments (Models 182,
428, 486, 487, 2000, 2001, 2002, 2010, 2015, 2016, 2400, 2410, 2420, 2430, 2510, 6430,
6517, 7001) side-by-side in a standard 19-inch rack.
Model 4288-3 side-by-side rack mount kit
— Mounts a Model 2510 and a Model 199
side-by-side in a standard 19-inch rack.
Model 4288-4 side-by-side rack mount kit
— Mounts a Model 2510 and a 5.25-inch
instrument (Models 195A, 196, 220, 224, 230, 263, 595, 614, 617, 705, 740, 775, etc.)
side-by-side in a standard 19-inch rack.
Model 4288-5 dual fixed rack mounting kit
— Mounts a Model 2510 and another 3
½
-
inch high instrument (Model 182, 428, 486, 487, 2000, 2010, 2400, 2410, 2420, 2430,
6430, or 7001), side-by-side in a standard 19-inch rack.
Carrying case
Model 1050 padded carrying case
A carrying case for a Model 2510. Includes handles
and a shoulder strap.
Product overview
The Model 2510 and 2510-AT TEC SourceMeters have the following operating
characteristics:
Thermoelectric cooler source range: ±10V DC at up to ±5A DC.
Temperature, voltage, current, and resistance control functions.
Software-controlled PID loop.
PID autotuning (Model 2510-AT only).
100
and 1000
RTD sensor ranges.
Several measurement functions including operating resistance, voltage, current,
and power, as well as AC resistance.
Compatible with RTD, thermistor, and solid-state thermal feedback elements.
Built-in IEEE-488 and RS-232 interfaces for remote operation.
Output enable circuit to automatically remove source signal when a test fixture lid
is open.
Digital I/O port allows control of other instruments.
Closed-cover calibration — The instrument can be calibrated either from the front
panel or remote interface.