Section 7: TSP command reference Model 2657A High Power System SourceMeter® Instrument Reference Manual
7-348 2657A-901-01 Rev. B/December 2012
Usage
state = tsplink.state
state
TSP-Link state (online or offline)
Details
When the instrument power is first turned on, the state is "offline". After tsplink.reset() function is
successful, the state is "online".
Example
state = tsplink.state
print(state)
Read the state of the TSP-Link. If it is online, the
output is:
online
Also see
tsplink.node (on page 7-345)
tsplink.reset()
(on page 7-347)
tsplink.trigger[N].assert()
This function simulates the occurrence of the trigger and generates the corresponding event ID.
Type TSP-Link accessible
Affected by Where saved Default value
Function Yes
Usage
tsplink.trigger[N].assert()
N
The trigger line (1 to 3)
Details
The set pulse width determines how long the trigger is asserted.
Example
tsplink.trigger[2].assert()
Asserts trigger on trigger line 2.
Also see
tsplink.trigger[N].clear() (on page 7-349)
tsplink.trigger[N].mode
(on page 7-350)
tsplink.trigger[N].overrun
(on page 7-352)
tsplink.trigger[N].pulsewidth
(on page 7-353)
tsplink.trigger[N].release()
(on page 7-353)
tsplink.trigger[N].stimulus
(on page 7-354)
tsplink.trigger[N].wait()
(on page 7-356)