IV2 Series User's Manual (Control Panel)
3. Tool Settings (Setting the Judgment Method of the Target of Standard Mode)
Advanced settings of the Pitch tool
Items Description Setting range Ref.
Edge Sensitivity Manual Adjustment
Manually adjust the sensitivity that
detects the edge that will become
the standard of reference for pitch
extraction.
1 to 100 (default: 50)
4-119To Live Image
The edge sensitivity can be adjusted
using the Live image of the target.
--
Edge Sensitivity
Auto Adjustment
Automatically adjust the sensitivity
that detects the edge that will become
the standard of reference for pitch
extraction.
--
Pitch Extraction
Method
Bright/Dark Mode
Select the method to extract the target
pitch.
Bright (default)
Extracts the pitches between
bright regions.
Dark
Extracts the pitches between
dark regions.
4-120
Meas. Mode
Select the measuring method for the
pitch extracted from a target.
Pin Pitch (default)
Measures the pitch between pins
from the center point of the pin.
Pin Width
Measures the width of each pin.
Narrow Pitch
Mode
Set when pitch width is narrow.
ON
Enables the narrow pitch mode.
OFF (default)
Disables the narrow pitch mode.
Scaling
Scaling
Set when a measurement value is to
be used for anomaly detection instead
of the matching rate.
ON
Enable scaling.
OFF (default)
Disable scaling.
4-121
Display Value
When scaling is enabled, input the
display value in relation to matching
rate (*) 100.
0.05 to 9999
(Maximum input digits: 4)
(default: 100.0)
Copy Setting
When scaling is enabled, copy the
scaling settings from another tool.
--
Tool Name
Auser-speciedname,suchasthe
name of the target, can be set for the
tool. Tool names can be checked on
the run screen.
“5 Running” (Page 5-1)
Up to 16 characters can be set. 4-121
* A matching rate of 100 indicates that the average value of all pitches on the target is completely matched to the master
image. The value which deviates the most from average value among all pitches becomes the matching rate for the tool.
Whenthenumberofpitchesisdi󰀨erentfromthenumberforthemasterimage,thematchingrateis0.
4