DIAGNOSTICS Error Codes
10DEC05
DG4825-1
Page
91 of 180
15007 - Communications Error between MCPU BD A2 and GALVO BD A4
15008 - Start of Scan Timeout
15012 - Communications Error between MCPU BOARD A2 and the PC
Description: The DMA process for the MASTER CENTRAL PROCESSING UNIT
BOARD A2 did not complete within the expected time.
Cause 1: The MASTER CENTRAL PROCESSING UNIT BOARD A2 malfunctioned.
Action: Do the checkout for the MASTER CENTRAL PROCESSING UNIT BOARD A2.
Cause 2: The DIGITIZER BOARD A3 malfunctioned.
Action: Do the checkout for the DIGITIZER BOARD A3.
Cause 3: The GALVO BOARD A4 malfunctioned.
Action: Do the checkout for the GALVO BOARD A4.
Description: A timeout occurred for the expected “START OF SCAN”.
Cause 1: The MASTER CENTRAL PROCESSING UNIT BOARD A2 malfunctioned.
Action: Do the checkout for the MASTER CENTRAL PROCESSING UNIT BOARD A2.
Cause 2: The DIGITIZER BOARD A3 malfunctioned.
Action: Do the checkout for the DIGITIZER BOARD A3.
Cause 3: The GALVO BOARD A4 malfunctioned.
Action: Do the checkout for the GALVO BOARD A4.
Description: Windows 2000 did not return a response to a message within a given
time.
Cause 1: The MASTER CENTRAL PROCESSING UNIT BOARD A2 malfunctioned.
Action: Do the checkout for the MASTER CENTRAL PROCESSING UNIT BOARD A2.
Cause 2: The TCP/IP connection malfunctioned.
Action: Check the TCP/IP connection to the computer. See Step 6, Page 10.