Subindex 4
Description read the default value
Unit see corresponding ASCII command
Access ro
PDO mapping not possible
Data type see corresponding ASCII command
Value range see corresponding ASCII command
EEPROM
Default value
Subindex 5
Description read the parameter format
Unit
Access ro
PDO mapping not possible
Data type see corresponding ASCII command
Value range see corresponding ASCII command
EEPROM
Default value
Possible parameter formats:
0 Function (no parameter, read-only) 7 INTEGER32
1 Function (INTEGER32 parameter) 8 UNSIGNED32
2 Function (INTEGER32 parameter with weighting 3) 9 INTEGER32 (weighting 3)
3 INTEGER8 10 INTEGER32 (weighting 3)
4 UNSIGNED8 11
5 INTEGER16 12 UNSIGNED32
6 UNSIGNED16 13 UNSIGNED16
Subindex 6
Description read the parameter check data
Unit
Access ro
PDO mapping not possible
Data type UNSIGNED32
Value range 0 ... 2
32
-1
EEPROM
Default value
Description:
0x00010000 After an alteration the variable must be saved and the controller must be reset.
0x00020000 Variable is saved in the serial EEPROM.
0x00200000 Variable is read-only, must not be written to over the bus.
Subindex 7 / 8
Description reserved
Unit
Access ro
PDO mapping not possible
Data type UNSIGNED32
Value range 0 ... 2
32
-1
EEPROM
Default value
S300-S700 CANopen | 6 Appendix
Kollmorgen | kdn.kollmorgen.com | December 2019 93

Table of Contents

Other manuals for Kollmorgen S300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kollmorgen S300 and is the answer not in the manual?

Kollmorgen S300 Specifications

General IconGeneral
BrandKollmorgen
ModelS300
CategoryAmplifier
LanguageEnglish

Related product manuals