11-46 Key Operator Mode
Key Operator Mode
Memory Switch [12]
This function allows you to change the Memory Settings listed below. Underlined
settings indicate factory settings. See pp. 11-48~11-50 for details on Memory Settings.
SW No. Item Setting (default is underlined)
No.01: Auto reset timer OFF/ 30sec./ 60 sec./ 90 sec./ 120 sec./ 150 sec./
180 sec./ 210 sec./ 240 sec./ 270 sec./ 300 sec.
No.02: AUTO/RESET effect Full-auto/ Initial setting
No.03: Load RADF effect RADF/ RADF + AUTO RESET
No.04: Non Image A. Erase ON/ APS/AMS only
No.05: RADF frame erasure None/ 1 mm/ 2 mm/ 3 mm/ 4 mm/ 5 mm
No.06: Auto tray switch OFF/ ON
No.07: Platen APS OFF/ ON
No.08: RADF APS OFF/ ON
No.09: ATS/APS (Bypass) OFF/ ON
No.10: ATS/APS SW (Tray 1) OFF/ ON
No.11: ATS/APS SW (Tray 2) OFF/ ON
No.12: ATS/APS SW (Tray 3) OFF/ ON
No.13: ATS/APS SW (Tray 4) OFF/ ON
No.14: Platen AMS OFF/ ON
No.15: RADF AMS OFF/ ON
No.16: Staple mode reset OFF/ ON
No.17: Key click sound OFF/ Low/ High
No.18: Job memory recall OFF/ ON
No.19: Sheet insertion Tray 1/ Tray 2/ Tray 3/ Tray 4/ Bypass
No.20: 5.5x8.5 orig. type Landscape/ Portrait
No.21: Rotation OFF/ ON/ APS/AMS/reduce/ APS/AMS only/ APS
only
No.22: 1 SHOT Indication 1 sec./ 2 sec./ 3 sec./ 4 sec./ 5 sec.