Parameters
90 Operating manual for INVEOR α | DOC01539818 - 0004 | 2017-01 | V2.0 EN
4.230 VO function Unit: integer
Relationship
to parameter:
1.054
1.131
1.150
4.231
4.232
5.010
5.011
5.090
Parameter
manual:
P. xy
Transfer status:
2
min.: 0 Own value
(to be entered!)
max.: 51
def.: 0
Selection of the process variable to which the output should switch.
26
28
29
30
31
32
33
34
35
36
37
38
39
50
51
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Continuation of table
Analogue input 1 (V 3.60 and higher)
PID target value (V 3.60 and higher)
PID actual value (V 3.60 and higher)
STO channel 1
STO channel 2
Nominal frequency value after ramp
Nominal frequency value
Actual speed value
Actual frequency value sum
Torque sum
Nominal frequency value after ramp sum
Nominal frequency value sum
Actual speed value sum
Motor current limit enabled
Nominal-actual comparison (para. 6.070 – 6.071)
4.231 VO-On Unit:
Relationship
to parameter:
4.230
Parameter
manual:
P. xy
Transfer status:
2
min.:
- 32767 Own value
(to be entered!)
max.: 32767
def.: 0
If the set process variable exceeds the switch-on limit, the output is set to 1.
4.232 VO-Off Unit:
Relationship
to parameter:
4.230
Parameter
manual:
P. xy
Transfer status:
2
min.:
- 32767 Own value
(to be entered!)
max.: 32767
def.: 0
If the set process variable exceeds the switch-off limit, the output is again set
to 0.