© KWB – Kraft und Wärme aus Biomasse GmbH IM Easyfire 10/2008 Page 109
11 Fuel extractor, type S with fabric tank
11 Fuel extractor, type S with fabric tank
11 FE “S” INCLINED WORM, FABRIC TANK
Solid ceiling F90
No sharp objects above the fabric tank
Min. RL 235
Worm can be extended with
worm conveyor extension
Extractor worm 1 – L1=184.2
Extractor worm 2 – L2=139.2
If the fabric tank will be set up in a separate room,
ventilation with at least 400 cm2 must be provided.
11.1 Pellet storage room requirements (FE type S with fabric tank)
Comply with the instructions in points 1.3 to 1.3.2 in the introduction!
Boiler room and storage room construction
KWB Easyfire GL
Suction system and lance (Extraction pot on the fabric tank)
Fire
extinguisher
Boiler room
door
T30 100/120
Boiler room
Fabric tank
Storage room door
T30 80/120
Cleaning door, top
Sweep door, bottom
Vent opening
Fire-safety
collar
STOP
SWITCH
Extraction pot
with lance
MA-Easyfire 10.2008_EN.indd 109MA-Easyfire 10.2008_EN.indd 109 30.03.2009 13:30:51 Uhr30.03.2009 13:30:51 Uhr