2 System installation
2.1.6 Final inspection
Ensure that all components have been properly mounted.
Check all electrical connections before you energise the system!
2.1.7 First commissioning, ash removal
Read section 3 and 4 before commissioning.
2.1.8 Emptying the ash container
The ash container is filled automatically by the ash worm. Check the fill level several times during the heating
season. The ash container must be emptied one to four times during the heating season depending on the size of
the system. The accumulating ash contains the remains of the fuel in concentrated form. It is a high-quality fertiliser
and can be disposed of on the compost heap or scattered in the forest.
2.1.8.1 Removing the ash container
1.) Open the toggle-type fasteners
Open both of the side toggle-type fasteners. Pull the ash container off
straight, from the front.
Open the toggle-type fasteners
Attention: When the ash container is pulled out the control unit displays a fault message – the system shuts off.
The fault message is automatically reset when the ash container is re-installed.
2.) Close the fill pipe
Seal the ash container before transport. To do this turn the cover plate
downward.
Comment: Prior to attaching the ash container to the boiler the cover
must be moved up again.
Close the fill pipe
3.) Pull out the transport handle
Press the two arrests on the container handle and pull the transport
handle carefully upward, ensuring that it is straight until again locks in
place.
Pull out the transport handle
MA-Easyfire 10.2008_EN.indd 26MA-Easyfire 10.2008_EN.indd 26 30.03.2009 13:29:58 Uhr30.03.2009 13:29:58 Uhr