© KWB – Kraft und Wärme aus Biomasse GmbH IM Easyfire 10/2008 Page 175
18.2 Hydraulic diagrams
18.2 Hydraulic diagrams
Base module with weather-sensitive control system,
one expansion module
and a combination buffer as load compensator
MBEH0007_A sheet 2/2
System description:
The hydraulic system consists of the boiler circuit, the distributor, and a combination buffer that is switched as load
compensator (VAR 1) in the bypass. The return flow boost is executed via a thermal valve (28) on at least 50 °C. The basic
module for boiler / DHWC & buffer control is equipped with a weather-sensitive control system for 2 heating circuits
(option) and is combined with a bus-capable expansion module (25). Two heating circuits are equipped with analogue
room control units (option), the two other heating circuits are equipped with digital room control units (option) for
remote control.
Menu basic settings
Parameters Settings
Return ow boost Thermal valve
Network settings Boiler External 2 Heat to target 2
Power output Heating mode
Boiler dependence Yes
Heating circuit/
heating circuit 0 Room sensor Boiler/0
Outdoor sensor Boiler
Function No
Group no. 0
Heating circuit/
heating circuit 1 Room sensor DRCU 1
Outdoor sensor Boiler
Function Yes
Group no. 0
Heating circuit/
heating circuit 2 Room sensor Boiler/2
Outdoor sensor Boiler
Function Yes
Group no. 0
Heating circuit/
heating circuit 3 Room sensor DRCU 2
Outdoor sensor Boiler
Function Yes
Group no. 0
Heating circuit/
heating circuit 4 Room sensor HCM 1/2
Outdoor sensor Boiler
Function Yes
Group no. 0
DHWC/DHWC 0 Function Yes or before
Group no. 0
DHWC/DHWC 1 Function No
Group no. 0
Buer/Buer 0 Function VAR1
Buer/Buer 1 Function No
Digital remote control/ Outdoor sensor Boiler
Digital remote control 1 Heating circuit 1 – 2 or 1 – 4
DHWC 0 – 0
Buer 0 – 0
Digital remote control/ Outdoor sensor Boiler
Digital remote control 2 Heating circuit 3 – 4 or 1 – 4
DHWC 0 – 0
Buer - - -
Hardware Heating circuit modules 1
Digital remote control 2
Plug-in modules O
Comment: None
Subject to change!
Tech. data sheet HYD-USP-MBEH0007_a, sheet 2/2, date: 14-07-06 StHo
MA-Easyfire 10.2008_EN.indd 175MA-Easyfire 10.2008_EN.indd 175 30.03.2009 13:32:15 Uhr30.03.2009 13:32:15 Uhr

Table of Contents

Other manuals for KWB Easyfire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KWB Easyfire and is the answer not in the manual?

KWB Easyfire Specifications

General IconGeneral
Fuel TypeWood pellets
Cleaning SystemAutomatic heat exchanger cleaning
Emission Class5
Nominal Heat Output10 kW
TypePellet heating system
Ash RemovalAutomatic
Heating capacity10 kW
Hopper capacity15 kg
Flue diameter130 mm