18.5 Instructions, pellet delivery
18.5 Instructions, pellet delivery
INSTRUCTIONS FOR PELLET SUPPLIERS
(
The outgoing air must be able to escape via minimum 170 cm² opening!
A extractor system is not required.
The air that is blown in escapes through the fabric of the tank and is filtered in this process.
The pressure can also be compensated via opened windows or doors.
(
Maximum fill pressure: 1.5 bar!
(
Only change the incline of the fill nozzle for residual emptying! (Step 4).
Details in this regard are provided under point 9.9.4.
Filling instructions – KWB fabric tank
1.) Switch off the pellet heating system!
2.) Connect all parts of the filling system together so that they are electrically
conductive!
Details are provided under point 9.9 “Filling instructions”.
3.) 2 fill couplings on the fabric tank
For optimal filling:
1. First fill to the height of the load-bearing spars via nozzle 1
2. Then fill to maximum capacity via nozzle 2
3. Finally fill to maximum capacity via nozzle 1.
4.) Emptying residues from the fill hose
Disengage the lock bolt to tilt the fill nozzle as desired.
To conclude fix the nozzle in place in the original position.