EasyManua.ls Logo

KWB Easyfire - Chimney - Cross-Section Measurement

KWB Easyfire
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 212 IM Easyfire 10/2008 © KWB – Kraft und Wärme aus Biomasse GmbH
18.4 Chimney
18.4 Chimney
Chimney – cross-section measurement
Pellet fired
boiler diagram
Wood pellets in accordance with ÖNORM M 7135
Calorific value 4.9 kWh/kg
Water content max. 10 % by mass
Bulk weight 650 kg/m³
Flue gas temperature 190 °C
Heating system boiler with draft required
Basic data:
Combustion temperature 190 °C
Necessary conveyor pressures of the fireplace in accordance with manufacturer’s information
Connecting piece: – Thermally insulated
– Ø identical to flue Ø or boiler connection
– Effective length 1/7 of the effective height, max. 3.0 m
– Redirectors 2 bends 90°, 1 inlet 90° + 1 contraction
Nominal heat output in kW
Effective chimney height in meters
Clear chimney diameter in cm
MA-Easyfire 10.2008_EN.indd 212MA-Easyfire 10.2008_EN.indd 212 30.03.2009 13:32:30 Uhr30.03.2009 13:32:30 Uhr