Page 132 IM Easyfire 10/2008 © KWB – Kraft und Wärme aus Biomasse GmbH
14 Suction conveyor, Pellet Stirrer Plus
14 Suction conveyor, Pellet Stirrer Plus
14.2 Installation instructions FE type GS
Acoustically decouple the fuel extractor
Place the supplied insulating elements under all support brackets. The bolted connection of the fuel extractor must
be surrounded by insulating elements on all sides.
Before installation
• Comply with the instructions in all diagrams. Install the FE so that the storage room space is optimally utilised.
• Ensure that the eject point is correctly positioned. Ensure that there is adequate space for maintenance tasks.
• Mark the position of the support brackets on the storage room floor.
• Check the evenness and incline of the floor.
• Use shims to align the support points horizontally.
Maintenance distances, storage room (MBDK0001 in section 17)
The specific installation steps for this FE system are described in section 12 and 13
14.3 Final inspection
Ensure that ALL components and connections are correctly installed!
To conclude, ensure that the conveyor system is free of foreign objects!