Page 98 IM Easyfire 10/2008 © KWB – Kraft und Wärme aus Biomasse GmbH
KWB fuel extractors
KWB fuel extractors
FE
Type GS
Section
14
Suction conveyor
Pellet Stirrer Plus
Wooden boards
Ricochet protection mat
Solid ceiling F90 Solid ceiling F90
Min. 30
Conveyor height without step max. 300
FE
Type GL
Section
15
Suction conveyor
Lance with fabric tank
Solid ceiling F90 Solid ceiling F90
ank
let transport hose
ax. length 25 m
Min. 30
without step max. 300
Boiler
Room
Pellet Storage Room
Section
16
Suction conveyor
Lance with buried tank
Buried Tank
y
Solid ceiling F90
ank
Pellet transport hose
max. length 25 m
FE
Type R
Section
17
Pellet Stirrer
F90
Solid ceiling F90
F90
F90
Ricochet protection mat
Inclined floor
Max. 15°
Wooden boards
Min. 70 cm
WL
=
total (max. 320 cm)
WL
=
open
Energy-saving
damper Ø 15 cm with
explosion damper
20 cm
WL = worm length
MA-Easyfire 10.2008_EN.indd 98MA-Easyfire 10.2008_EN.indd 98 30.03.2009 13:30:32 Uhr30.03.2009 13:30:32 Uhr