2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-6
FAX U631 Comm Ctrl 2 It is set up whether transmission and
reception can be performed in ECM.
The frequency of CED is set up.
U632 Comm Ctrl 3 It is set up whether sending out after bit33
of a DIS/DTC signal is performed.
The number of times of CNG detection at
the time of a FAX/TEL automatic change is
set up.
U633 Comm Ctrl 4 It is whether communication by V.34 is per-
mitted, and transmission and reception -- it
sets up individually.
It is set up whether 3429 Hz in V.34 symbol
speed is used.
The number of times of reception of a DIS
signal is set up.
A RTN signal sending-out judging standard
(rate of an error line) is set up.
U634 Comm Ctrl 5 The judging standard of TCF is set up.
U640 Comm Time 1 The detection time at the time of one shot
selection of a remote change is set up.
The detection time at the time of the contin-
uous selection of a remote change is set
up.
U641 Comm Time 2 The timeout time at the time of FAX com-
munication is set up.
U650 Modem 1 G3 cable equalizer is set up.
A modem disregard level is set up.
U651 Modem 2 A modem outgoing level is set up.
U660 Set Calls A setup relevant to NCU (network control
unit) is carried out.
U670 Output List The list of the data relevant to facsimile
communication is outputted.
U699 Set Soft SW A setup of the softswitch on a FAX control
circuit board is set up individually.
Section
Item
No.
Content of maintenance item Summary