2NC/2NF/2NG/2NN/3P7/3P8/3P9-2
1-3-5
Image pro-
cessing
U402 Adjust margin The space of a leading edge, AC side, and
a trailing edge is adjusted.
U403 Scan Margin Tbl The margin of reading data is adjusted by
picture reading by a scanner.
U404 Scan margin DP The margin of reading data is adjusted by
picture reading by DP
U411 Scanner Auto Adjustment A scanner and DP are adjusted automati-
cally.
U425 Set Target The target value of an adjustment original
is set up.
FAX U600 Init All Data According to the country code and the
OEM code which were inputted, all the
softswitches, backup data, and an image
memory are initialized.
U601 Init Keep Data Softswitches other than machine data are
initialized according to the country code
and the OEM code which were inputted.
U603 User Data 1 A circuit class is set up.
U604 User Data 2 The number of times of a bell at the time of
a FAX/TEL automatic change is set up.
U605 Clr Data All the data of a communication history and
a protocol list is cleared.
U610 System Setting 1 The number of waste lines at the time of
degree, the number of waste lines at the
time of automatic reduction, and the num-
ber of waste lines at the time of automatic
reduction (A4, LETTER) are set up.
U611 System Setting 2 The number of adjustment lines at the time
of automatic reduction and the number of
adjustment lines at the time of automatic
reduction (A4, LETTER) are set up.
U615 System Setting 6 Recording width capability and a disposal
method when an 11-inch width recording
form is set by an inch system are set up.
U620 FAX System Remote change mode (a continued type /
one shot type) is set up.
U625 Set Comm The interval of a redial and the number of
times are set up.
U630 Comm Ctrl 1 Transmitting start speed and receiving abil-
ity speed are set up.
The measure against an echo at the time
of transmission/reception is set up.
Section
Item
No.
Content of maintenance item Summary