Server models with middle/rear drive bays
This section provides thermal information for server models with middle or rear drive bays.
S/S: SAS/SATA; Any: AnyBay 
Front bays Middle 
bays
Rear bays
CPU 
TDP* 
(watts)
Max. 
Ambient 
Temp. 
(at sea 
level)
Heat sink Air 
baffle
Fan type Max. 
PMEM 
Qty.
24 x 2.5" S/S 
16 x 2.5" S/S + 
8 x Any
NA 4 x 2.5" S/S <= 205 30°C
Standard 
2U
Stand-
ard
Perform-
ance
16
24 x 2.5" Any 8 x 2.5" Any
NA
105–150 30°C
Standard 
1U
None
Perform-
ance
16
165–205 30°C
Perform-
ance (T- 
shape)
None
Perform-
ance
16
24 x 2.5" S/S  8 x 2.5" S/S
4 x 2.5" S/S
8 x 2.5" S/S
105–150 30°C
Standard 
1U
None
Perform-
ance
16
165–205 30°C
Perform-
ance (T- 
shape)
None
Perform-
ance
16
12 x 3.5" S/S 
NA
2 x 3.5" S/S
4 x 2.5" S/S
4 x 3.5" S/S
<= 205 30°C
Standard 
2U
Stand-
ard
Perform-
ance
4
8 x 2.5" Any
NA
105–150 30°C
Standard 
1U
None
Perform-
ance
4
165–205 30°C
Perform-
ance (T- 
shape)
None
Perform-
ance
4
4 x 3.5" S/S
4 x 2.5" S/S
4 x 3.5" S/S
105–150 30°C
Standard 
1U
None
Perform-
ance
4
165–205 30°C
Perform-
ance (T- 
shape)
None
Perform-
ance
4
12 x 3.5" Any
NA 4 x 3.5" S/S <= 205 30°C
Standard 
2U
Stand-
ard
Perform-
ance
4
4 x 3.5" S/S 4 x 3.5" S/S
105–150 30°C
Standard 
1U
None
Perform-
ance
4
165–205 30°C
Perform-
ance (T- 
shape)
None
Perform-
ance
4
Note: *The Intel Xeon 6334 HCC 165W processor is not included. When this processor is used, middle drive 
bays or rear drive bays are not supported.
194