Icon Funcon
Load oscillogram / conguraon from
le
Load recorded oscillogram from the device
Save oscillogram in le
Copy oscillogram to the clipboard
Print oscillogram
Display cursor
Centre cursor
Scale curve
automacally
Acvate zoom
funcon
"Time base:" Display of the set me base
Tool sengs (right-hand side of the toolbar)
Technical data
Number of channels 1 ... 8
Data memory depth Maximally 2048 measured values for each channel
Data width of a channel Maximally 64 bits, according to the data type of the parameter to be recorded
Sample rate 62.5 µs or a mulple thereof
Minimum recording me 128 ms
(62.5 µs * 2048 measur
ed values)
Maximum me base 20.47 s
Maximum recording
me
20.47 s
Trigger level According to the value range of the parameter to be triggered
Trigger selecon
Trigger delay -100 % ... +400 %
Trigger source Channel 1 ... 8
Addional
funcons
Oscilloscope funcon