Selecng parameters to be recorded
The oscilloscope supports up to eight channels, thus maximally eight parameters can be recor-
ded in an oscillogr
am. The Channels list eld serves to congure the parameters to be recor-
ded as signal sources:
Col-
umn
Name Meaning
1 - Curve colour for the representaon in the oscillogram
2 Ch Channel number
3 On on / o
4 Inv Inversion on / o
5 Name Selecon of the parameter to be recorded
6 yPos I Value at cursor I in vercal
direcon
7 yPos II Value at cursor II in vercal direcon
8 | ΔyPos | Dierence between the two values of yPos I and yPos II (displayed as amount)
9 Unit Scaling
10 AS Acvaon / deacvaon of the autoscaling funcon
11 1 / Div
12 Oset The oset value is subtracted from the recorded raw value before the scaling is execu-
ted. This serves to, e. g., make very small value uctuaons visible within one consis-
tently very high recording value (e. g. harmonics with a low amplitude).
13 Posion Regarding the vercal curve scale -5 ... 5, the posion value determines the vercal
posion of the zero point of the Y axis of a curve.
How to select a parameter for recording:
1.
Double-click the "Name" column in the Channel list eld to open the "Selecon of signal
sources" dialog box.
2.Select the parameters to be recorded in the dialog box.
3.Press the "Ok" buon. This closes the dialog box and the selecon is accepted.
4.Repeat the steps 1 ... 3 to select up to seven further parameters to be recorded.
The selected parameters are recorded when the oscilloscope is started.
How to change a parameter for recording:
1.Double-click the parameter to be changed in the Channels list eld in the "Name" column.
2.Make a new selecon in the "Selecon of signal sources" dialog box.
3.Press the "Ok" buon. This closes the dialog box and the selecon is accepted.
The changed parameters are recorded when the oscilloscope is started.
How to cancel a selecon again:
1.Right-click the parameter to be removed in the Channels list eld in the "Name" column to
open the context menu.
2.Select the "Remove parameter" command in the context menu.
The selected and changed parameter will not be recorded anymore when the oscilloscope is
started.
Dening the recording me / sample rate
Addional
funcons
Oscilloscope funcon