Source of the master value
When changing the parameter, the inverter must be inhibited.
The master values for the technology applicaon come from a variety of sources. The source
is selected via the Master value source parameter. 0x5020:014
The following sources can be selected:
System bus
Load encoder
Virtual master
Analog input 1
Parameter
Address Name / seng range / [default seng] Info
0x4000 Applicaon
selecon
Seng can only be changed if the inverter is inhibi-
ted.
0 "CiA 402" technology applicaon
10 "Speed Control" technology applicaon
20 "Table Posioning" technology applicaon
40 "Electronic Gearbox" technology applicaon
41 "Sync and Correcon" technology applica-
on
50 "Winder Dancer" technology applicaon
51 "Winder Tension" technology applicaon
10000 "User" technology applicaon
Conguring the "Winder Dancer" TA
90