EasyManua.ls Logo

Lenze L-force 9400 Series - Page 147

Lenze L-force 9400 Series
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EDS94ARNExxxx EN 2.3 - 06/2014 L 147
9400 regenerative power supply module | Parameter setting
"CAN on board" system bus
Implemented CANopen objects
I-1000
The CANopen index I-1000 specifies the device profile for this device. Furthermore,
additional information defined in the device profile itself can be stored here.
[6-1] Assignment of the data telegram
I-1001
Error register
This object is related to the Lenze code C00390
.
The error state in the data byte (U8) is bit-coded (see below table). At the moment, only
bit 0 and bit 4 of the data byte contain the corresponding information.
Index
I-1000
Name:
Device type
Subindex Default setting Display range (min. value | unit | max. value) Access Data type
0: Device type 0
0 4294967295 ro U32
8th byte 7th byte 6th byte 5th byte
Data 4 Data 3 Data 2 Data 1
High word Low word
High byte Low byte High byte Low byte
Additional information Device profile number
Index:
I-1001
Name:
Error register
Subindex Default setting Display range (min. value | unit | max. value) Access Data type
0: Error register - 0 255 ro U8
Bit Meaning when the bit is set:
Bit 0 Generic error
Bit 1 Current error (not used)
Bit 2 Voltage error (not used)
Bit 3 Temperature error (not used)
Bit 4 Communication error
Bit 5 Device-profile-specific error (not used)
Bit 6 Reserved
Bit 7 Manufacturer-specific error (not used)