9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C02801
338 L EDS94ARNExxxx EN 2.3 - 06/2014
C02801
C02802
C02803
C02810
Parameter | Name:
C02801 | Analog output x: Output signal
Data type: INTEGER_16
Index: 21774
d
= 550E
h
Scaling: -16384 ≡ -100 %, +16383 ≡ +100 %
Display range (min. value | unit | max. value)
-16384 16383
Subcodes Information
C02801/1 Analog output 1: Output signal
C02801/2 Analog output 2: Output signal
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C02802 | Status word: Digital outputs
Data type: BITFIELD_32
Index: 21773
d
= 550D
h
Display of the hexadecimal value of the digital outputs
• Important: All digital levels are indicated without considering the level logic. Internal signals are displayed as
well.
Display range (min. value | unit | max. value)
0x 0x
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C02803 | Status word: Digital inputs
Data type: BITFIELD_32
Index: 21772
d
= 550C
h
Display of the hexadecimal value of the digital inputs
• Important: All digital levels are indicated without considering the level logic. Internal signals are displayed as
well.
Display range (min. value | unit | max. value)
0x 0x
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C02810 | Touch probe x: Delay time
Data type: UNSIGNED_32
Index: 21765
d
= 5505
h
The set delay time will be considered when the position is determined at the touch probe time and will be used to
compensate for dead times, if necessary.
• Please observe also the setting of the input filter for the digital inputs (C02830
).
Setting range (min. value | unit | max. value)
0 μs 7000
Subcodes Lenze setting Information
C02810/1 0 μs TP1 (DI1): Delay time
C02810/2 0 μs TP2 (DI2): Delay time
C02810/3 0 μs TP3 (DI3): Delay time
C02810/4 0 μs TP4 (DI4): Delay time
C02810/5 0 μs TP5 (DI5): Delay time
C02810/6 0 μs TP6 (DI6): Delay time
C02810/7 0 μs TP7 (DI7): Delay time
C02810/8 0 μs TP8 (DI8): Delay time
C02810/9 0 μsTPM (motor encoder): Delay time
C02810/10 0 μsTPL (pos. encoder): Delay time
Read access Write access CINH PLC STOP No transfer