EDS94ARNExxxx EN 2.3 - 06/2014 L 337
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C02756
C02756
C02757
C02800
Parameter | Name:
C02756 | LI_ActualOutState
Data type: UNSIGNED_8
Index: 21819
d
= 553B
h
From software version V2.0 onwards
Display of the digital output signals of the line interface
Selection list (display only) Information
0 FALSE
1 TRUE
Subcodes Information
C02756/1 LI_bDeviceOverloadWarning
C02756/2 LI_bFilterOverloadWarning
C02756/3 LI_bMainsVoltageOk
C02756/4 LI_bOperational
C02756/5 LI_bLimitationActive
C02756/6 LI_bRegenActive
C02756/7 LI_bChopperIsActive
C02756/8 LI_bChopperOffByTrouble
C02756/9 LI_bLineVoltageWarning
C02756/10 LI_bLineUndervoltageError
C02756/11 LI_bLineOvervoltageError
C02756/12 LI_bDCBusLowerThanSetValue
C02756/13 LI_bFilterOvertemperature
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C02757 | LI_ActualInState
Data type: UNSIGNED_8
Index: 21818
d
= 553A
h
From software version V2.0 onwards
Display of the digital input signals of the line interface
Selection list (display only) Information
0 FALSE
1 TRUE
Subcodes Information
C02757/1 LI_bChopperTurnOn
C02757/2 Reserved
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C02800 | Analog input x: Input signal
Data type: INTEGER_16
Index: 21775
d
= 550F
h
Scaling: -16384 ≡ -100 %, +16383 ≡ +100 %
Display range (min. value | unit | max. value)
-16384 16383
Subcodes Information
C02800/1 Analog input 1: Input signal
C02800/2 Analog input 2: Input signal
Read access Write access CINH PLC STOP No transfer