9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C02752
336 L EDS94ARNExxxx EN 2.3 - 06/2014
C02752
C02753
C02754
C02755
Parameter | Name:
C02752 | LI_dnActualLineVoltage
Data type: INTEGER_32
Index: 21823
d
= 553F
h
From software version V2.0 onwards
Current mains voltage in [%]
100 % 1000 V
Display range (min. value | unit | max. value)
0.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02753 | LI_dnActualPower
Data type: INTEGER_32
Index: 21822
d
= 553E
h
From software version V2.0 onwards
Current power in [%]
100 % P
max_device
(C00057)
Display range (min. value | unit | max. value)
-2147483647 W 2147483647
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C02754 | LI_dnActualThermalLoadDevice
Data type: INTEGER_32
Index: 21821
d
= 553D
h
From software version V2.0 onwards
Thermal device utilisation in [%]
Current result of the Ixt calculation.
Display range (min. value | unit | max. value)
0.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02755 | LI_dnActualThermalLoadFilter
Data type: INTEGER_32
Index: 21820
d
= 553C
h
From software version V2.0 onwards
Thermal filter utilisation in [%]
Display range (min. value | unit | max. value)
0.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100