EDS94ARNExxxx EN 2.3 - 06/2014 L 335
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C02732
C02732
C02733
C02734
C02750
C02751
Parameter | Name:
C02732 | Analog inputs: Dead band
Data type: INTEGER_32
Index: 21843
d
= 5553
h
Setting range (min. value | unit | max. value)
0.00 % 100.00
Subcodes Lenze setting Information
C02732/1 0.00 % Analog input 1: Dead band
C02732/2 0.00 % Analog input 2: Dead band
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02733 | Analog outputs: Gain
Data type: INTEGER_32
Index: 21842
d
= 5552
h
Setting range (min. value | unit | max. value)
-200.00 % 200.00
Subcodes Lenze setting Information
C02733/1 100.00 % Analog output 1: Gain
C02733/2 100.00 % Analog output 2: Gain
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02734 | Analog outputs: Offset
Data type: INTEGER_32
Index: 21841
d
= 5551
h
Setting range (min. value | unit | max. value)
-200.00 % 200.00
Subcodes Lenze setting Information
C02734/1 0.00 % Analog output 1: Offset
C02734/2 0.00 % Analog output 2: Offset
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02750 | LI_dnActualDCBusVoltage
Data type: INTEGER_32
Index: 21825
d
= 5541
h
From software version V2.0 onwards
Current DC-bus voltage in [%]
• 100 % ≡ 1000 V
Display range (min. value | unit | max. value)
0.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C02751 | LI_dnActualLineCurrent
Data type: INTEGER_32
Index: 21824
d
= 5540
h
From software version V2.0 onwards
Current mains current in [%]
• 100 % ≡ I
max_device
(C00789)
Display range (min. value | unit | max. value)
0.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100