9400 regenerative power supply module | Parameter setting
Device interface
Device commands
72 L EDS94ARNExxxx EN 2.3 - 06/2014
Possible status displays for these device commands
Related device commands
Archive parameter sets 1 ... 4
( 73)
Status (C00003) Meaning
for command
201
for command
202
for command
203
for command
204
13206786 13272322 13337858 13403394 Device command in process
13172736 13238272 13303808 13369344 Device command executed successfully
13172731 13238273 13303809 13369345 General fault
13206532 13272068 13337604 13403140 File could not be opened.
13206557 13272093 13337629 13403165 Fault while reading out of a file.
13206558 13272094 13337630 13403166 Fault while writing to a file.
13206559 13272095 13337631 13403167 Invalid file type.
13206560 13272096 13337632 13403168 Unexpected file end.
13206562 13272098 13337634 13403170 Checksum error
13212160 13277696 13343232 13408768 CAN fault
... ... ... ... ...
13212415 13277951 13343487 13409023 CAN fault
13213697 13279233 13344769 13410305 Access to file has been denied since the file is
already accessed from another position.
13213701 13279237 13344773 13410309 I/O fault during accessing the file system
13213708 13279244 13344780 13410316 RAM memory is full
13213709 13279245 13344781 13410317 Access authorisation denied
13213724 13279260 13344796 13410332 No free memory on the memory module