Additional Instructions for correct use:
Follow the instructions for use carefully.
Use the bed exclusively if it is in perfect working order.
If necessary, check the bed functions daily or at each shift change.
Ensure any user has read and understood this manual completely before operating the product.
Use the bed exclusively with the correct mains supply.
Ensure that the bed is operated exclusively by qualied personnel who have been trained according to the instructions for
use.
Ensure the bed is operated by qualified personnel trained in using the bed in accordance with the instructions for use by
manufacturer or by person approved by the manufacturer, eventually by authorized representative or by person approved by the
authorized representative.
Ensure that the patient (health permitting) has been informed about the operation of the bed and all applicable safety
instructions.
Contact service department of the manufacturer immediately to let it replace any damaged parts by the original spare
parts.
Move the bed exclusively on even, hard-surfaced oors.
Replace any damaged parts immediately with original spare parts.
Ensure that maintenance and installation are performed exclusively by qualied personnel who have been trained by the
manufacturer.
Before peak loads or unavoidable excess loads (CPR), place Mattress Support Platform to the lowest position.
Ensure that only one adult patient lies on the bed at any time.
Take care to avoid injuries or squeezing when operating moving parts.
When using lifting pole or infusion stand, ensure that nothing will be damaged when you move or adjust the bed.
Brake the castors when the bed is occupied.
Keep the Mattress Support Platform in the lowest position when the patient is unattended by healthcare personnel in order
to minimize risk of patient falls.
Ensure that siderails are operated exclusively by healthcare personnel.
Never use the bed in areas where there is a hazard of explosion.
Enable or disable functions on control elements as appropriate for the patient’s physical and mental state. Afterwards
ensure the lock function was used as required.
Ensure that parts of the bed intended for movement are not blocked.
Never handle the mains plug with wet hands.
Disconnect the product from the mains exclusively by pulling the mains plug.
When pulling the mains plug, always hold the plug, not the cable.
Position the mains cable so that there are no loops or kinks in the cable. Protect the cable from mechanical wear and tear.
Improper handling of mains cable can cause an electric shock hazard, other serious injuries or damage to the integrated
mattress system.
Ensure that the stipulated duty cycle of motor is not exceeded.
To change fuses or cables contact servise organisation authorized by manufacturer.
To prevent failures, use exclusively the manufacturer’s original accessories and mattresses.
Ensure that the stipulated safe working load is not exceeded.
If the patient‘s condition could lead to an entrapment, leave the mattress support platform in the at position whilst una-
ttended.
Adjust bed height when transporting the bed in order to facilitate overcoming possible obstacles.
Do not exceed maximum load of 80 kg for mattress support platform extension.
Do not hang anything on any cable.
Do not modify bed and its components without the manufacturer´s approval.
Use the mattress exclusively as specied in this manual and in perfect working order.
Use the mattress exclusively in its original state and do not modify it in any way.
Have the mattress used exclusively by or under supervision of trained and qualied nursing personnel.
Have the mattress serviced and installed exclusively by qualied personnel trained and authorised by the manufacturer.
Do not exceed the maximum patient weight limit (see Mechanical Specications).
Do not use the bed in the case its parts have been removed unless these parts are designed to be removed.
To avoid injury or crushing, take extra caution when operating any moving parts of the bed.
Never use the mattress replacement system compatible with the Essenza 300 bed near radiators or other heat sources.
Select a suitable location for the placement of bed accessories and other objects to prevent involuntary activation of
buttons or controls which may result in the adjustment of bed positioning.
Never place any accessories or Handset Control Panel on the siderails where keyboards are located.
After each emergency situation always check if any of the control elements is not involuntarily pressed by the bed acces-
sories or by the mattress.
To avoid unintended activation of moving parts during any use of the bed always check that none of the control elements
of the bed is pressed by persons, mattress or other objects.
When adjusting the Lateral Tilt in the case of Essenza 300 with Lateral Tilt, ensure that the process does not pose any risk
of the patient falling or getting injured, or of any lines or tracheal tubes getting pulled out.