ELECTRIC SYSTEM 16000 SERVICE/MAINTENANCE MANUAL
3-18
Published 05-09-17, Control # 014-28
56-n EC1A Load Hoist (Drum 2) Motor Speed Sensor
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN52-2 *2
56-p EC1B Load Hoist (Drum 2) Motor Speed Sensor
1.2 or 3.2 Volts Not Moving;
2.2 Volts Moving
CAN52-2 *2
*1 – Lower four bits can be multiplied by 5 or 10 depending on sender, then divided by 16 for an estimation of sender voltage.
*2 – Number in indicated bank should increment in positive direction and decrement in negative direction with item rotation.
*3 –
Swing Lock removed on current production cranes.