Grove Published 3-22-2021, Control # 702-02 4-155
GRT8120 OPERATOR MANUAL OPERATING PROCEDURES
To inhibit, or prevent, the exhaust system from entering the
active cleaning mode or to stop the exhaust cleaning
process that was manually initiated, do the following:
1. Using the Jog Dial or the Up/Down Arrow Buttons on the
Navigation Control Pad, select the Inhibit Cleaning
Process Icon (1, Figure 4-167) (icon changes to
orange).
2. Press the Jog Dial or OK Button on the Navigation
Control Pad to set the cleaning process to inhibit (Inhibit
Cleaning Process Icon changes to green).
The Inhibit Exhaust System Cleaning Indicator comes
on in the Alerts Area of the ODM, and the active and
manual modes of exhaust system cleaning are
prevented.
Service Menu
Select the Service Menu icon (1, Figure 4-168) under the
User Settings Menu Group to show the Service Menu
function screen.
The Service Menu function screen is accessible to those
service technicians who have attended the Grove New
Technology training course.