150 Using the RFID Functions
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual logiJET T4-2 /T6-2 /RFID Edition 2.2
Please note the following hints, if the automatic transponder position
measurement routine fails:
Note: Please always carry out several automatic transponder position
measurements. This is necessary to find the right transponder
position of your label material.
The RFID tag was not found in the RF Field (area
inside the printer where RFID tag is read)
- check supply loading
- rerun the automatic transponder position
measurement
- further remedies are listed below
The RFID tag was found in the RF Field, but could not
be read.
- increase the number of retries
See section 10.2.4 Adjusting the Number of
RFID Access.
- rerun the automatic transponder position
measurement
- Set the transponder position manually
(see next page).
- If there is still no proper access to the RFID tags
inspite of setting the right transponder position value
manually, please choose a different material.