190 Troubleshooting
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual logiJET T4-2 /T6-2 /RFID Edition 2.2
12.3. Incorrect Media Transport
Defect
Remedies
Incorrect media transport
(no gap detection between
labels e.g.)
Panel display:
[Paper Jam ]
or
[Punch Error ]
or
[Sync.Mark.Error ]
- perform the basic operations
(see chapter 4)
- check if the Sync Sensor has been adjusted
correctly (see section 9.3 up to 9.4)
- check if the media has been loaded
correctly
(compare section 5.2)
- check if the ribbon has been loaded
correctly
(compare section 5.3)
- clean the transport rollers
(see section 11.1.3)
No straight transport of the
consumables
(torsion or folding of the
ribbon, e.g.)
- check if the ribbon has been loaded
correctly
(compare section 5.3)
- check if the media has been loaded
correctly
(compare section 5.2)
- check if the printhead pressure was
adjusted correctly
(see section 5.4 and section 11.3)
- clean the transport rollers
(see section 11.1.3)
Paper Jam
in addition to the remedies above:
- release the printhead pressure lever to
remove the paper (compare chapter 5)
- check if the jammed consumables have
been removed completely.
If the remedies above are not successful, please call a MICROPLEX
authorized service engineer.