168 Using the RFID Functions
_______________________________________________________________________________________________
_______________________________________________________________________________________________
MICROPLEX Operator’s Manual logiJET T4-2 /T6-2 /RFID Edition 2.2
10.6. RFID Errors
Pay attention to the hints given in chapter 12 Troubleshooting!
Check if the RFID material has been inserted correctly, clear paper
jams.
Only use RFID material that is suitable for your printer.
Unreadable Transponder Identification Number:
If the printer can not read and send the transponder identification number
of the label (Label ID), the printer marks the print image as an error label
(two black bars are printed on the label).
After the printing of this label the printer sends a 1000 or a 1020
message with an “X” instead of the label ID via the status channel.
Compare section 10.4.2 and section 10.4.4.
Hint: The panel function described in section 10.2.4 is used to set the
maximum number of unsuccessful RFID accesses (read, program, etc.)
being allowed until the printer treats this label as defective.