Parameters: Each rf command contains one or more type codes. Most of these
type codes are followed by an appropriate parameter.
Permissible values of the rf command parameters <k
xx
nn> :
Terminate RFID processing
of the current label (label that is below
the RF Write/Read module of the
printer).
Please refer to the example in figure
10.4.1.a. This command can be used
to teminate RFID processing of label B
in order to cut label A immediately.
Hint: the ID number of label B is
available only if it was read
previously.
Read ID
Reads the transponder (label ID
number), the answer is sent to the host
(via the printer SOLID status channel;
ASCII formatted).
Data block number
When writing:
00 = EPC* = default
01 = user
When reading:
nn = block number
Data format
0 = binary = default
(ASCII presented as they are)
1 = Hex-ASCII
*EPC: Electronic Product Code