Syntax of the command <ESC><ESC>ee:
<ESC><ESC>ee <ddd> <hhhh>
Parameter <ddd> : The word which should be set (here: 023).
Parameter <hhhh> : The new value for the specified word.
The words of the EEPROM sequence are coded in HEX. If you want to
change one bit of a word, you have to program the complete word. It is not
possible to change one bit only.
Example:
Word <FFFF>
To change bit 13 to "0" the new value for the word is <EFFF>.
The start value of the word may differ from the value described above. The
value depends on the configuration of the printer.
To set the word no. 23 to the new value <EFFF>, send the command
<ESC><ESC>ee 023 EFFF to the printer.
After power off and on the new value will be valid.