Steps to set the Switching Threshold (Sync.Sens.Level) at the printer panel:
Panel display
[ON LINE ]
[OFF LINE ]
[Menu Level 1 ]
[Engine ]
[Printspeed ]
[Sync. Menu ]
[Auto.Sens.Adj. ]
[Sync.Sens.Level ]
[Level: 44% 40.0% ]
[Level: 44% 28.0% ]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this key.
The ENTER key gives the user access to
the menu structure.
Press the NEXT or PREVIOUS key until
[Engine ] is displayed.
Press the ENTER key, this selects the
Engine menu.
Press the NEXT or PREVIOUS key until
[Sync. Menu ] is displayed.
Press the ENTER key, this selects the
Sync.Menu.
Press the NEXT or PREVIOUS key until
[Sync.Sens.Level ] is displayed.
Press the ENTER key to set the
switching threshold of the sensor.
The measured contrast value is
displayed at the left; the currently set
level is displayed at the right side.
Press the UP or DOWN key until the
desired sensor level is displayed.
In this example the switching threshold
is set to 28%.
In addition this new value can be saved
as setup value (using the ENTER key).
After this decision turn the printer
ONLINE again: Press the ONLINE key
longer than 2 seconds.
Sensor measured value
Switching Threshold