EasyManuals Logo

Mindray uMEC15 User Manual

Mindray uMEC15
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #189 background imageLoading...
Page #189 background image
21-3
21.6 Setting Up Reports
21.6.1 Setting Up ECG Reports
You can print out ECG reports only under full-screen, half-screen or 12-lead monitoring
screen. To set up ECG reports, select [Main Menu]Ä—[Print Setup >>]Ä—[ECG
Reports >>].
 [Amplitude]: set the amplitude of the ECG waveforms.
 [Sweep]: set the wave print speed to 25 mm/s or 50 mm/s.
 [Auto Interval]: If [Auto Interval] is set to [On], the system will automatically adjust
the space between waveforms to avoid overlapping.
 [12-Lead Format]: If you select [12
h
1], 12 waveforms will be printed on a paper from
top to bottom. If you select [6
h
2], 12 waveforms will be printed from left to right with
6 waveforms on each half part and a rhythm waveform will be printed at the bottommost.
If you select [3
h
4+1], 12 waveforms will be printed from left to right with 3
waveforms on each of the 4 columns and a rhythm waveform will be printed at the
bottommost.
21.6.2 Setting Up Tabular Trends Reports
To set up tabular trends reports, select [Main Menu]Ä—[Print Setup >>]Ä—[Tabular Trends
Reports >>].
 Date: Select the desired date on which a tabular trends report is recorded for printing.
 Start time: You can set a time period whose trend data will be printed out by setting
[From] and [Back]. For example, if you set [From] as 2007-4-2 10: 00: 00 and [Back]
as [2 h], the outputted data will be from 2007-4-2 08: 00: 00 to 2007-4-2 10: 00: 00. In
addition, the [Back] can be set to either:
 [Auto]: If [Report Layout] is set to [Time Oriented], the report will be printed by
time. If [Report Layout] is set to [Parameter Oriented], the report will be printed
by parameters.
 [All]: If you select [All], all trend data will be printed out. In this case, it is no need
to set [From].
 [Spacing]: choose the resolution of the tabular trends printed on the report.
 [NIBP]: prints a tabular trends report when NIBP measurements were acquired.
Each NIBP measurement will generate a column in the tabular trends review
window. The values for the other measurements are added to the column to provide
a complete dataset for the NIBP measurement time.
 [Auto]: prints a tabular trends report during the period selected and at the interval
set in the [Interval] option. The [Interval] option is located at the bottom the
[Tabular Trends] tab of the [Review] window.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray uMEC15 and is the answer not in the manual?

Mindray uMEC15 Specifications

General IconGeneral
BrandMindray
ModeluMEC15
CategoryMedical Equipment
LanguageEnglish

Related product manuals