IV - 55
Appendix 7. Explanation of Alarms
Appendix 7.2 Stop Codes (T)
T01 Cycle st. prohibit(Host comm.) 0115
Details
Automatic start cannot is not possible because the NC is communicating with the host
computer.
Remedy
- Wait for the communication with host computer to be ended and then execute the
automatic start.
T01 Cycle st prohibit(Battery alm) 0116
Details
Automatic start is not possible because the voltage of the battery in the NC control unit has
dropped.
Remedy
- Replace the battery of the NC control unit.
- Contact the service center.
T01 R-pnt offset value not set 0117
Details
Automatic operation is not possible because no reference position offset value has been set.
Remedy
- Perform the reference position initialization setting, then set "#2034 rfpofs(Distance-coded
reference position detection offset)".
T01 Cycle start prohibit 0118
Details
Tool retract position signal OFF
The axis was moved from the tool retract position. Tool retract position reached signal is
OFF.
Remedy
Once the axis has been moved off the tool retract position, resuming the program is not
possible. Cancel the program by reset and then execute it from the start.
T01 In absolute position alarm 0138
Details
A start signal was input during an absolute position detection alarm.
Remedy
- Clear the absolute position detection alarm, and then input the start signal.
T01 In abs posn initial setting 0139
Details
A start signal was input during zero point initialization in the absolute position detection
system.
Remedy
- Complete zero point initialization before inputting the start signal.
T01 Start during MDI operation at other part system disable 0141
Details
In multi-part system, a start signal was input for MDI mode while the MDI operation was
being carried out in another part system.
Remedy
- End the other part system's operation before starting.