EasyManuals Logo

Mitsubishi C70 User Manual

Mitsubishi C70
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #404 background imageLoading...
Page #404 background image
IV - 59
Appendix 7. Explanation of Alarms
Appendix 7.2 Stop Codes (T)
T10 Fin wait 0200
Details
Waiting for completion of G11
G11 was issued while an axis was moving.
Remedy
Resume the operation after G11 has been completed.
T10 Fin wait 0ooo
Details
The following Nos. are shown during the operation of the corresponding completion wait
factor. The numbers will disappear when the operation is completed.
The completion wait factor is indicated with four digits (in hexadecimal).
Display format of completion wait factor
0__ __ __
(a)(b)(c)
Each of the hexadecimal numbers (a), (b) and (c) indicates the following details.
(a)
bit0: In dwell execution
bit3: Unclamp signal wait (Note 1)
(b)
bit0: Waiting for spindle position to be looped
bit3: Door open (Note 2)
(c)
bit0: Waiting for MSTB completion
bit1: Waiting for rapid traverse deceleration
bit2: Waiting for cutting speed deceleration
bit3: Waiting for spindle orientation to com
(Note 1) This shows the wait state for the unclamp signal's ON/OFF for the index table
indexing.
(Note 2) This shows the door open state caused by the door interlock function.