EasyManua.ls Logo

Mitsubishi C70

Mitsubishi C70
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IV - 170
Appendix 7. Explanation of Alarms
Appendix 7.12 Program Errors (P)
P223 G12 G13 R ERR
Details
The radius value specified with a G12 or G13 command is below the compensation amount.
Remedy
- Correct the program.
P224 NO G12‚ G13 SPC
Details
There are no circular cutting specifications.
Remedy
- Check the specifications.
P230 NESTING OVER
Details
Over 8 times of subprogram calls have been done in succession from a subprogram.
- A M198 command was found in the program in the data server.
- The program in the IC card has been called more than once (the program in the IC card
can be called only once during nested).
Remedy
- Correct the program so that the number of subprogram calls does not exceed 8 times.
P231 NO N-NUMBER
Details
The sequence No., commanded at the return from the subprogram or by GOTO in the
subprogram call, was not set.
Remedy
- Specify the sequence Nos. in the call block of the subprogram.
P232 NO PROGRAM No.
Details
- The machining program has not been found when the machining program is called.
- The file name of the program registered in IC card is not corresponding to O No.
Remedy
- Enter the machining program.
- Check the subprogram storage destination parameters.
- Ensure that the external device (including IC card) that contains the file is mounted.
P241 NO VARl NUMBER
Details
The variable No. commanded is out of the range specified in the specifications.
Remedy
- Check the specifications.
- Correct the program variable No.
P242 EQL. SYM. MSSG.
Details
The "=" sign has not been commanded when a variable is defined.
Remedy
- Designate the "=" sign in the variable definition of the program.

Table of Contents