IV - 174
Appendix 7. Explanation of Alarms
Appendix 7.12 Program Errors (P)
P360 NO PROG.MIRR.
Details
A mirror image (G50.1 or G51.1) command has been issued though the programmable
mirror image specifications are not provided.
Remedy
- Check the specifications.
P380 NO CORNER R/C
Details
The corner R/C was issued though it is out of specifications.
Remedy
- Check the specifications.
- Delete the corner chamfering/corner rounding command in the program.
P381 NO ARC R/C SPC
Details
Corner chamfering II or corner rounding II was commanded in the arc interpolation block
though it is out of specifications.
Remedy
- Check the specifications.
P382 CORNER NO MOVE
Details
The block next to corner chamfering/ corner rounding is not a travel command.
Remedy
- Replace the block succeeding the corner chamfering/ corner rounding command by G01
command.
P383 CORNER SHORT
Details
The travel distance in the corner chamfering/corner rounding command was shorter than the
value in the corner chamfering/corner rounding command.
Remedy
- Set the smaller value for the corner chamfering/corner rounding than the travel distance.
P384 CORNER SHORT
Details
The travel distance in the following block in the corner chamfering/corner rounding
command was shorter than the value in the corner chamfering/corner rounding command.
Remedy
- Set the smaller value for the corner chamfering/corner rounding than the travel distance in
the following block.
P385 G0 G33 IN CONR
Details
A block with corner chamfering/corner rounding was given during G00 or G33 modal.
Remedy
- Correct the program.