IV - 175
Appendix 7. Explanation of Alarms
Appendix 7.12 Program Errors (P)
P390 NO GEOMETRIC
Details
A geometric command was issued though it is out of specifications.
Remedy
- Check the specifications.
P391 NO GEOMETRIC 2
Details
There are no geometric IB specifications.
Remedy
- Check the specifications.
P392 LES AGL (GEOMT)
Details
The angular difference between the geometric line and line is 1° or less.
Remedy
- Correct the geometric angle.
P393 INC ERR (GEOMT)
Details
The second geometric block has a command with an incremental value.
Remedy
- Issue a command with an absolute value in the second geometric block.
P394 NO G01 (GEOMT)
Details
The second geometric block contains no linear command.
Remedy
- Issue the G01 command.
P395 NO ADRS (GEOMT)
Details
The geometric format is invalid.
Remedy
- Correct the program.
P396 PL CHG. (GEOMT)
Details
A plane switching command was issued during geometric command processing.
Remedy
- Complete the plane switching command before geometric command processing.
P397 ARC ERR (GEOMT)
Details
In geometric IB, the circular arc end point does not contact or cross the next block start
point.
Remedy
- Correct the geometric circular arc command and the preceding and following commands.