8 Manual Control
8.3 Manual pulse generator operation
150
FX3U-20SSC-H Positioning Block User's Manual
8.3.2 Current manual pulse input value
The current number of total input pulses from the manual pulse generator is stored.
The current value is added in normal rotation, and subtracted in reverse rotation.
The stored data does not include the manual pulse generator input magnification.
8.3.3 Input frequency of manual pulse generator
The frequency of the manual pulse generator inputs is stored.
The sign of an increasing count is positive (+), while the sign of a decreasing count is negative (-).
The stored data does not include the manual pulse generator input magnification.
BFM Number
Data type
X-axis Y-axis
Manual pulse generator input
current value
BFM #13, #12 BFM #113, #112 Monitor data
BFM Number
Data type
X-axis Y-axis
Manual pulse generator input
frequency
BFM #15, #14 BFM #115, #114 Monitor data