11 Buffer Memory (Parameters & Monitored Data)
11.3 Monitor Data
236
FX3U-20SSC-H Positioning Block User's Manual
11.3.33 Servo status 2 [BFM #72, BFM #172]
11.3.34 Flash memory write count [BFM #91, #90]
The number of times data is written to the flash memory is stored.
Note
The maximum number of writes to the built-in flash memory is 100,000 times.
BFM Number
Bit
Number
Description Value Format Default
X-axis Y-axis
BFM #72 BFM #172
b0
A parameter update completed flag
This bit is set when an automatic update of servo
parameters is completed.
Cleared when a servo parameter save command or
servo parameter initialization command is finished.
Bit -
b1
Parameter updating flag
This bit is ON while servo parameters are being updated.
b2
Parameter update request flag
This bit turns ON when the servo amplifier sends servo
parameter update request.
b3 to b15 Not available
BFM Number
Description Value Format Default
X-axis Y-axis
BFM #91,#90 - The number of writes to the flash memory Decimal -