Appendix A: LIST OF PARAMETERS AND DATA
Appendix A-2 Control Data Table
282
FX3U-20SSC-H Positioning Block User's Manual
Appendix A-2 Control Data Table
BFM number
Item Description/Setting range
Default
value
Reference
X axis Y axis
BFM
#501,#500
BFM
#601,#600
Target address1
-2,147,483,648 to 2,147,483,647 (user unit)
*1
K0 Subsection 11.4.1
BFM
#503,#502
BFM
#603,#602
Operation speed1
1 to 2,147,483,647 (user unit)
*1
*2
K1 Subsection 11.4.2
BFM
#505,504
BFM
#605,#604
Target address2
-2,147,483,648 to 2,147,483,647 (user unit)
*1
K0 Subsection 11.4.3
BFM
#507,#506
BFM
#607,#606
Operation speed2
1 to 2,147,483,647 (user unit)
*1
*2
K1 Subsection 11.4.4
BFM #508 BFM #608 Override setting 1 to 30000 (×0.1%) K1000 Subsection 11.4.5
BFM #510 BFM #610
Torque output setting
value
0 to 10000 (×0.1%) K0 Subsection 11.4.6
BFM
#513,#512
BFM
#613,#612
Speed change value
1 to 2,147,483,647 (user unit)
*1
*2
K1 Subsection 11.4.7
BFM
#515,#514
BFM
#615,#614
Target position
change value
(address)
-2,147,483,648 to 2,147,483,647 (user unit)
*1
K0 Subsection 11.4.8
BFM
#517,#516
BFM
#617,#616
Target position
change value
(speed)
1 to 2,147,483,647 (user unit)
*1
K0 Subsection 11.4.9
BFM #518 BFM #618 Operation command 1
b0 Error reset
b1 STOP (Deceleration stop)
b2 Forward rotation limit (LSF)
b3 Reverse rotation limit (LSR)
b4 Forward rotation JOG
b5 Reverse rotation JOG
b6 Mechanical zero return command
b7 Not available
b8 Relative/absolute address specification
b9 START command
b10 Simultaneous START flag
*3
b11 m code OFF
b12 Change command in operation disabled
b13 Speed change command in positioning operation
b14 Target position change command in positioning operation
b15 Not available
H0000 Subsection 11.4.10
BFM #519 BFM #619 Operation command 2
b0 Remaining distance operation cancel command
b1 System reset command (Ver.1.10 or later)
*4
b3, b2 Not available
b4 Positioning parameter enable command
b5 Acceleration/deceleration time change command
(Ver.1.30 or later)
b6 Mode selection for the Interrupt 1-speed constant
quantity feed (Ver.1.10 or later)
b7 Interrupt 1-speed Constant Quantity Feed (Constant
position stop mode) shortest allowable stop
(Ver.1.30 or later)
b8 Servo OFF command
b9 Servo parameter transfer command
b10 Gain change command
b11 Servo parameter update stop (Ver.1.10 or later)
b15 to b12 Not available
H0000 Subsection 11.4.11
BFM #520 BFM #620
Operation pattern
selection
b0 1-speed positioning
b1 Interrupt 1-speed constant quantity feed
b2 2-speed positioning
b3 Interrupt 2-speed constant quantity feed
b4 Interrupt stop
b5 Variable speed operation
b6 Manual pulse generator operation
b7 Linear interpolation
b8 Linear interpolation (interrupt stop)
b9 Table operation (individual)
b10 Table operation (simultaneous)
b11 Reciprocal movement instruction (Ver.1.10 or later)
b15 to b12 Not available
H0000 Subsection 11.4.12