Mitsubishi FX3U-20SSC-H - Monitor Data; Current Address (User) [BFM #1, #0, BFM #101, #100]; Current Address (Pulse) [BFM #3, #2, BFM #103, #102]

Mitsubishi FX3U-20SSC-H
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 Buffer Memory (Parameters & Monitored Data)
11.3 Monitor Data
226
FX3U-20SSC-H Positioning Block User's Manual
11.3 Monitor Data
Operating conditions for the positioning system are stored as monitor data. The following buffer memories for
monitor data are read-only memories except for the current address (user) [BFM #1, #0 (X-axis), BFM #101,
#100 (Y-axis)].
For X-axis: BFM #0 to #99
For Y-axis: BFM #100 to #199
Caution
Do not use unlisted BFMs for changing values not described in this section.
11.3.1 Current address (User) [BFM #1, #0, BFM #101, #100]
The current address data is stored in units specified by the user
*1
.
*1. Refer to the section shown below for details on the user units.
Refer to Section 7.10
POINT
The stored address data is always handled as an absolute address.
The unit of the value is a user-specified one and includes a magnification setting for position data.
The unit and magnification setting can be specified by the operation parameters 1.
For details on the operation parameters 1, refer to Subsection 11.1.1
It is possible to change the current address of a stopped axis to any address.
Overwrite the current address (user) with a new address. The current address will be changed and its
pulse data will be updated.
Set a value within the range from 0 to the ring value during the ring operation.
For details on the current address change function, refer to Subsection 7.9.9
11.3.2 Current address (Pulse) [BFM #3, #2, BFM #103, #102]
The current address is converted into pulses and stored.
POINT
The stored address data is always handled as an absolute address (converted pulse data).
For details on the converted pulse data, refer to Section 7.10
It is possible to change the current address of a stopped axis to any address.
Overwrite the current address (user) with a new address. The current address will be changed and its
pulse data will be updated.
Set a value within the range from 0 to the ring value during the ring operation.
For details on the current address change function, refer to Subsection 7.9.9
BFM Number
Description Value Format Default
X-axis Y-axis
BFM #1,#0
BFM
#101,#100
-2,147,483,648 to 2,147,483,647 (user unit)
*1
Decimal -
BFM Number
Description Value Format Default
X-axis Y-axis
BFM #3,#2
BFM
#103,#102
-2,147,483,648 to 2,147,483,647 PLS Decimal -