EasyManua.ls Logo

Mitsubishi FX3U-20SSC-H - M Code; 10.9.1 after Mode

Mitsubishi FX3U-20SSC-H
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Table Operation
10.9 m code
200
FX3U-20SSC-H Positioning Block User's Manual
10.9 m code
The m code is an auxiliary command to support positioning data in execution.
When an m code turns ON in table operation, the 20SSC-H stores the table No. in monitor data as an m code
number, while also turning ON the m code ON flag in status information.
There are two modes for m code, after mode and with mode, and each mode has a different ON timing.
10.9.1 After mode
The specified m code turns ON after the operation.
1. Operation
1) When the table No. 0 operation with m code "10" ends, the m code ON flag in the status information turns
ON, and the 20SSC-H stores "10" in the m code No. of monitor data.
2) At m code OFF, the m code ON flag and m code itself turns OFF, and the 20SSC-H stores "-1" in the m
code No. of monitor data.
3) At m code OFF, the 20SSC-H executes the next table No..
For the parameters, control data and monitor data, refer to Chapter 11
Note
With after-mode m codes in multi-speed operations and continuous pass operations, the operation does
not continue the table since the 20SSC-H suspends the operation until m code OFF.
With "0" in m code information, the 20SSC-H turns to standby mode. With start command or m code OFF
command, the m code turns OFF.
To turn only the m code ON without performing positioning operation, set "m code" to the operation
information of the table information, and set the m code information.
2. Available m code Nos.
To use m code in the after mode, set the m code in the range from 0 to 9999 for the m code information.
Mode Content m code No.
after mode The m code turns ON when the operation of table information is completed. 0 to 9999
with mode The m code turns ON when the operation information begins. 10000 to 32767
BFM number
Data type
X-axis Y-axis
m code OFF command Operation command 1 BFM #518 b11 BFM #618 b11 Control data
m code number BFM #9 BFM #109 Monitor data
Number of the table in operation BFM #16 BFM #116 Monitor data
m code ON Status information BFM #28 b8 BFM #128 b8 Monitor data
m code ON
m code No.
Speed
Time
m code OFF command
-1
OFF
OFF OFF
OFF OFF
ON
ON ON
ON
-110 11
Table No. Operation information m code information
0
1
10
(after mode)
(1-speed positioning)
(after mode)
(no processing)
(END)
1
-1
11
20 -1

Table of Contents