11 Buffer Memory (Parameters & Monitored Data)
11.2 Servo Parameters
221
FX3U-20SSC-H Positioning Block User's Manual
11
Buffer Memory
12
Program
Example
13
Diagnostics
A
List of
Parameters and
Data
B
Version
Information
BFM
#15052
BFM
#15252
PB34
Gain changing
Vibration
suppression control
resonance frequency
setting
Set the resonance frequency for vibration suppression control when the
gain changing is valid.
Setting range: 1 to 1000 (× 0.1 Hz)
K1000
BFM
#15063
BFM
#15263
PB45
Vibration
suppression control
filter 2
(Ver.1.40 or later)
Set the vibration suppression control filter 2 setting frequency selection
and notch depth selection.
Vibration suppression control filter 2 setting frequency selection
0: Disable
1: 2250 Hz
5F: 4.5 Hz
Notch depth selection
0: Deep (-40.0db)
F: Shallow (-0.6db)
H0000
BFM Number Servo
Amplifier
Parameter No.
Name Description Default
X-axis Y-axis
Vibration suppression control filter 2
setting frequency selection
0
Notch depth selection