8-41
Chapter 8 FUEL SYSTEM
3.2.4 Fuel Control Link - Install and Adjust
Left-bank linkage - Overall view
5612
5612
Stop lever
Governor lever
Control lever
126.5 ± 0.3 mm
[4.980 ± 0.012 in.]
126.5 ± 0.3 mm
[4.980 ± 0.012 in.]
147mm
[5.787 in.]
147mm
[5.787 in.]
147mm
[5.787 in.]
124mm
[4.882 in.]
Adjustable length
control rink A
Adjustable length
control rink A
Governor lever
Adjustable length
control rink C
Adjustable length
control rink C
Stop lever
Control lever
Adjustable length
control link B-2
Adjustable length
control link B-2
Woodward ProAct actuator spec
Toho Seisakusho SG4017 actuator PTA2 spec
8°
16.1°
8°
39.7°
Rack "0": 67.5 mm [2.60 in.]
Play: approx. 2 mm [0.12 in.]
Rack "0": 67.5 mm [2.60 in.]
Play: approx. 2 mm [0.12 in.]
Fuel injection pump
Fuel injection pump
Distance from the end of
fuel injection pump
to the holecenter of rack end
to the holecenter of rack end
Distance from the end of
fuel injection pump to
the hole center of rack end
Distance from the end of
fuel injection pump
to the holecenter of rack end
147mm
[5.787 in.]
124mm
[4.882 in.]