1 Open the CRYPTRManagement application.
2 In the Application Configuration screen, from the pull down menu, select SDIO. Click OK.
3 Login as admin.
4 Click CRYPTR Upgrade. The CRYPTR Upgrade window pops up.
5 Browse to C:\Program Files (x86)\Motorola MCC 7100\bin\red_cryptr_upgrade.prod.binC:\Program
Files (x86)\Motorola\Motorola CRYPTR micro Support Applications\Driver. Select
red_cryptr_upgrade.prod.bin.
6 To initiate programming, click Start Upgrade. If ejection of the CRYPTR micro is required, the utility
prompts you to do so.
The version of CRYPTR micro software can be verified post-upgrade by using
CRYPTRManagementapplication:
1 Insert the CRYPTR micro into the SD slot.
2 Open the CRYPTR micro Management application.
3 To see the CRYPTR micro version numbers, view the contents of About... box.
Disabling FIPS
To support Digital Encryption Standard – Output FeedBack (DES-OFB) and ADP encryption
algorithms, first disable Federal Information Processing Standards (FIPS) in the Windows operating
system.
Procedure:
1 Disable FIPS by performing one of the following actions:
If… Then…
If you disable FIPS
in systems where
the console is joined
to an ASTRO
®
25 do-
main,
perform one of the following actions:
•
If you configure a dispatch IP console, join it to the Windows7
MCC7100 IP Consoles with Ext Voice Encryption Organiza-
tional Unit (OU).
• If you configure a patch IP console, join it to the Windows7
MCC7100 Patch IP Consoles with Ext Voice Encryption OU.
See “Joining and Rejoining a Windows-Based Device to an Active
Directory Domain with a Script” in the Windows Supplemental Con-
figuration manual.
If you disable FIPS
in systems where
the console is out-
side the Radio Net-
work Infrastructure
(RNI) and is joined
to a Customer Enter-
prise Network (CEN)
domain,
a Import the MCC 7100 FIPS Disable Outside RNI Console
Group Policy Object (GPO). See Importing Group Policy Ob-
jects into a Customer Enterprise Network Domain on page 62.
b Link the MCC 7100 FIPS Disable Outside RNI Console GPO
to the appropriate OU for the console on the CEN domain con-
troller.
The correct order of linking the GPO is of crucial importance. The
MCC 7100 FIPS Disable Outside RNI Console GPO must be at
the top of the link order. For detailed instructions, see the appropri-
ate documentation and contact the CEN network administrator.
If you disable FIPS
in K core systems or
on an MCC 7100 IP
perform the “Applying Device-Specific Settings Using the Windows
Supplemental CD” procedure from the Windows Supplemental
Configuration manual.
MN000672A01-E
Chapter 2: MCC 7100 IP Dispatch Console Setup and Installation
Send Feedback 71